Plans Howe Sound Chart
-
Selectable AC-Transducer 13 TAS-311DG
TAS-311DG is a micro-controller-based AC-transducer with 1 analogue output for measurement of RMS-voltages, RMS current, phase angle or frequency on an AC-network. The PC configuration software allows free choice of voltage, current, phase angle or frequency measurement including configuration of the measuring range and output range without any mechanical settings or adjustments inside the transducer.The transducer holds no mechanical moving parts like potentiometers and therefore the calibration stability is excellent. TAS-311DG can be delivered pre-configured or it can be delivered un-configured for customer configuration through the PC-interface. Features: Measures voltage, current, frequency or phase angle on AC networksClass 0.5 (IEC-688) measurementSupply and measuring voltage up to 690VEasy configuration via PC-interface possibleNon-linear output characteristics possible
-
Selectable AC-Transducer 13 TAS-331DG
TAS-331DG is a micro-controller-based AC-transducer with 1 analogue output for measurement of power or reactive power on an AC-network. The transducer holds no mechanical moving parts like potentiometers and therefore the calibration stability is excellent.TAS-331DG can be delivered pre-configured to the desired measuring value and range or it can be delivered un-configured for customer configuration through the PC-interface. The PC-configuration makes free adjustment of the full input range and output range possible without any mechanical settings or adjustments inside the transducers.Features: Measures power or reactive power on 3-phase AC networksClass 0.5 (IEC-688) measurementSupply and measuring voltage up to 690VEasy configuration via PC-interface possibleNon-linear output characteristics possible
-
AC Current Single Function Transducer 13 TAC-321DG
The current transducer types TAC-311DG or TAC-321DG are transducers for measurement of a sinusoidal AC current converted into a DC current signal proportional to the measured value on a single-phase network.PLCs, PCs, microprocessor control, indicators, alarm units etc. can be operated by the output signal.Features:Wide range of standard measuring/output rangesCompact design, 55 x 75 mmEasily accessible terminalsEasy identification of unit/functionAccuracy class 0.535 mm DIN rail or base mounting
-
AC Voltage Single Function Transducer 13 TAV-311DG
The voltage transducers type TAV-311DG or TAV-321DG are transducers for measurement of a sinusoidal AC voltage converted into a DC current or DC voltage signal proportional to the measured value on a single-phase or 3-phase network. PLCs, PCs, microprocessor control, indicators, alarm units etc. can be operated by the output signal.Features:Wide range of standard measuring/output rangesCompact design, 55 x 75 mmEasily accessible terminalsEasy identification of unit/functionAccuracy class 0.535 mm DIN rail or base mounting
-
AC Voltage Single Function Transducer, TAV-321DG
The voltage transducers type TAV-311DG or TAV-321DG are transducers for measurement of a sinusoidal AC voltage converted into a DC current or DC voltage signal proportional to the measured value on a single-phase or 3-phase network. PLCs, PCs, microprocessor control, indicators, alarm units etc. can be operated by the output signal.Features: Wide range of standard measuring/output rangesCompact design, 55 x 75 mmEasily accessible terminalsEasy identification of unit/functionAccuracy class 0.535 mm DIN rail or base mounting
-
Insulation Amplifier, TDG-210DG
TDG-210DG is a CE-marked DC/DC amplifier with galvanic separation between input and output.Featuring:Converting one type of DC signal into another DC signalConverting potentiometer input into a DC signalSeparating a number of earthing pointsGalvanic separation of current signalsConversion of measuring signalAdaption of measuring rangeSeparation of measuring circuitsMeasuring on DC shuntsMeasuring of DC voltages
-
Battery Charger and Power Supply, DCP2 (12V, 24V)
Using switch mode technology to ensure an extremely low ripple, the DCP2 is a safe choice both as a battery charger and/or a DC power supply.Furthermore high efficiency, automatically protections and low weight are key words in most applications.Features: Automatic and electronic protection featuresAutomatic restart after fault conditionsAutomatic output power derating for high ambient temperaturesGreen LED indication for aux. power connectedAdjustable output voltageNo moving parts 13 no maintenanceDin rail mountedType approvals from all major classification societies
-
Battery Charger, DBC-1
Tested and certified as a first grade quality unit with a robust aluminium housing and black plastic cover, the DBC-1 has a long and reliable product life and withstands years of everyday wear and tear.Using switch mode technology to reduce energy waste, the unit is also vibration-resistant and features dry contact alarm relay activation in cases of fault detection, as well as boost/equalisation for extended battery lifetime, and advanced overvoltage (transient) protection.Features: Automatic and electronic protection featuresAutomatic restart after fault conditionAlarm relayAutomatic output power derating for high ambient temperaturesLED indication of faults, boost charging and normal operationBoost modeAdjustable output voltageNo moving parts 13 no maintenanceType approvals from all major classification societies
-
Multi-Transducer 13 MTR-3
DEIF 19s multi-transducer is used for measuring on single-phase and 3-phase network topologies. All measurements are available on the RS485 Modbus communication and up to four analogue outputs can rapidly and easily be configured by a USB 2.0 interface.MTR-3 provides a cost-effective, compact and powerful solution for your transducer application.AAFeatures:AASuitable for all 1- and 3-phase network topologiesAUp to 1000VL-L AC inputAClass 0.5/0.3 accuracyAUp to 4 analogue outputsAMeasures more than 50 parametersARS485 serial Modbus communicationAFully configurable by USB, no aux. supply requiredAUniversal power supply of 19-300V DC/40-276V AC